1100°C Max. Compact Atmosphere Controlled RTP Furnace with 50ºC/S Heating Rate for <= 3" Wafer - OTF1200XRTP4

1100°C Max. Compact Atmosphere Controlled RTP Furnace with 50ºC/S Heating Rate for <= 3" Wafer - OTF1200XRTP4

Minimum Order: $20 (equipment), $100 (crystals)

Shipping and handling will be applied

Price: RFQ

SKU: 

Choose Your Variant or Type in Any Add-Ons:



View full details

OTF-1200X-RTP-4 is a compact rapid thermal processing tube furnace that is designed for annealing semiconductor wafers or solar cells with diameters up to 3". 8 units of 1KW halogen light heat OTF-1200X-4-RTP with a max. heating rate of 50ºC/second. A 30-segment precision temperature controller with +/-1ºC accuracy is built into the furnace to allow for heating, dwelling, and cooling at various steps. RS485 port and control software are included to make monitoring the temperature profile via PC while simultaneously running the furnace possible. This furnace can also be modified into an RTE, CSS, or HPCVD furnace ( see below application note )
SPECIFICATIONS
Furnace Structure
  • Double-layer steel casing with air cooling keeps furnace surface temperature lower than 60°C.
  • High-purity fibrous alumina insulation for maximum energy saving.
  • Split cover with Interlock protection; cuts the power if the lid is opened during the furnace heating process.

Power Input

208-240 AC, 50/60 Hz, single-phase, 9 KW Max. (60A breaker required)


Heating Elements

  • 8 pcs 1Kw Halogen light tube, ( Dia. =10mm, L=300mm, Heated Length =200mm)
  • Standard working life: 2000 hrs. ( depends on heating rate )
  • The Halogen light tube is consumable. Please click the picture on the left to order a spare one
               

Heating Zone

12" length with 4" constant temperature zone within +/-5ºC uniformity

Working Temperature

  • 1100ºC Max. for < 10 minutes
  • 1000ºC Max. for < 20 minutes (Note: if running longer, furnace case will be> 100°C; must use a fan to cool the furnace case from outside)
  • 800ºC Max. for < 120 minutes
  • 600ºC Max. for Continuous 

Max. Heating Rate

  • 50ºC/sec
    Recommended 5 ºC/s, up to 1000ºC

Cooling Rate

  • Max. Cooling: 60ºC/min (Under vacuum: 200 m-torr), 117ºC/min (under atmospheric pressure) 
  • Lowest Cooling: 10 ºC / minute

Thermocouple

K type; the head of the thermocouple touches the Aluminum Nitride sample holder from underneath

Temperature Controller

  • FA-YD808P-AG temperature controller is included.
  • Proportional–integral–derivative control (PID control) and auto-tune function
  • 30 segments programmed with ramping, cooling and dwelling steps
  • Built-in over-temperature alarm and thermocouple failure alarm
  • +/- 1 ºC temperature control accuracy
  • Default DB9 PC communication port

Temperature controller (optional)

Quartz Tube & Sample Holder

               

Vacuum Flange

  • The KF-D25 high-vacuum flange is made of stainless steel with double high-temp. silicone O-rings, needle valves, and a water-cooling jacket.
  • It only requires water cooling for long run times at temperatures > 600oC.
  • Circulating water rate: 0.5 m3 /hr.
  • The slide-out flange provides an easier way of loading and unloading the samples and other specific processes needed.
  • Insertable thermocouple for accurate measurement. 

Vacuum Pump (optional)

  • EQ-FYP vacuum pump is recommended for this furnace. The ultimate vacuum pressure in this system can be 10^-3 torr. Vacuum bellows and clamps are included in this package. Click here for the specs of the EQ-FYP vacuum pump. 
  • Click here to view other models of pump and package.

Water Cooling (optional)

  • Cooling water is required.
  • Please ensure the cooling water flow rate is ≥ 10 L/min, water temp. < 25ºC; pressure > 25 PSI.
  • We suggest using the EQ-KJ5000 Series recirculating water chiller as a cooling system (please order separately at related products below) to save water.
  • Warning: This RTP furnace's max dwelling time shall be less than 600 seconds at 1000ºC ~ 1100ºC with tap water; otherwise, the O-ring may melt. 

Flow-meter

One flow meter is installed on the front panel for adjusting gas flow from 16 - 160 ml/min

Vacuum Gauge

A digital vacuum gauge with a measurement range from 10-4 to 1000 Torr is installed on the furnace.

Vacuum Pressure & Gas Fitting

  • Pressure can reach 50 Torr using a mechanical vacuum pump with a KF25 adapter
  • Pressure can reach 10^-4 Torr with a molecular pump with a KF25 adapter

Laptop, software & Control(Optional)

   
  • Brand new laptop with Microsoft Windows 10 and Microsoft Office 2013 (30-day free trial) for immediate use.
  • LabVIEW-based Temperature Control System (MTS01)enables the user to edit temperature profiles, manage heat-treatment recipes, record, and plot data for MTI furnaces.

Compliance

Please select the certificate in the options bar:
UL or CSA certificate (UL 61010) is available upon request at an extra cost

  • Pattern Number: ZL-2011-2-0077168.4 SINCE 2011-3-22

Application Notes

  • Tube furnaces with quartz tubes are designed for use under vacuum and ambient pressure < 0.2 bars / 3 psig / 0.02 MPa. Vacuum pressures may only be safely used up to 1000°CThe flow rate for gases should be limited to<200 SCCM (or 200ml/min) to reduce thermal shocks to the tube
  • Attention: A two-stage pressure regulator must be installed on the gas cylinder to limit the pressure to below 3 PSI for safe operation. Click here to learn the installation of a gas regulator.
  • This furnace can also be modified into an RTE, CSS or HPCVD furnace with a graphite crucible coated with SiC ( click Pic-left for details on how to set up an RTE process by DIY )
  • After CVD, the graphene must be transferred from the metal catalyst to another substrate for most applications. Using graphene transfer tape reduces residue.

STANDARD PACKAGE

Item No.

Description

Quantity

Quick Links

CVM-211

Digital Vacuum Gauge Up to 10-4 Torr

1

KF-Valve-D25

Vacuum Ball Valve with Dual KF-D25 port

1

RTP-ACC-01

Sample Holder for RTP furnace

1

AIN-Holder

Aluminum Nitride Substrate for RTP Furnace's Sample Holder

1

QZTube-RTP

Quartz Tube: 4.33" O.D x 4.05" I.D x 16.2" Length for RTP Tube Furnace

1

RTP-ACC-02

Quartz heat shield disk

4

WCT-12

20ft. polyurethane tube O.D. 12mm I.D. 8mm W.P. 100PSI

1

SOR-110

Inner Rubber O-Ring 110 mm Diameter (4 pcs preinstalled)

8 in total

SOR-128

Outer Rubber O-Ring 128 mm Diameter (2 pcs preinstalled)

4 in total

RTP-Halogen-light

Halogen light

8

MTI-WATER-CONN

Water Hose Connector

2

KF-Clamp-D25

Quick Clamp with Rubber O-Ring for KF-D25 Vacuum Adapter

2

TC-K-Cali-12S-DT-LD

K-Type Thermocouple

1

 

Dimension:

  •  Flange closed: 1350mm(L) x 330mm(W) x 590mm(H)
  •  Flange opened: 1350mm(L) x 520mm(W) x 740mm(H)

Net Weight:

  • 70 kg (150 lbs)

Shipping:

  • Shipping Dimension: 47"x39"x40"
  • Shipping Weight: 220 lbs

MTI offers a One-Year limited warranty for this product.

The MTI One Year Limited Warranty does NOT cover

  • Consumable parts, such as graphite dies, O-rings, crucibles, screws, washers, glassware, etc.
  • Any damage and rust resulting from improper storage or maintenance.
  • Any damages caused by the use of corrosive and acidic gases.
  • Any damage resulting from failing to adhere to the individual product's specific operation requirements, such as water cooling, venting, etc.