MSK-115A-MS is a 4-in-1 compact hot sealer. It integrates the functions: Side Sealing; Purging; Vacuum Standing; and Vacuum Sealing. The machine is compatible with the dry room and the glove box with Argon and Nitrogen atmosphere. The vacuum level, the relative positive pressure level, the vacuum, and pressure times are adjustable. The purging function will remove the oxygen and moisture in the chamber and helps the solid-state pouch cell batteries to form a better SEI layer during the first cycling. It is a perfect lab tool for liquid, semi-solid-state, or solid-state pouch cell battery research, as well as metal-gas (eg: Li-O2, Li-CO2, Al-CO2) batteries.
SPECIFICATIONS:
Input Power
Single-phase 110 VAC or 208-240 VAC (selectable at Product Options), 50 / 60 Hz
700 W power
Control Panel
4.5" touch screen panel controls all necessary parameters for automatic operation, including:
Purging pressure and time, as well cycle time ( -90KPa - 100Pa)
Sealing mode: side / top-sealing without vacuum or Vacuum sealing
The highest vacuum level is 10-2 torr by mechanical pump and 10-4-torr by turbopump
Click the picture to order a vacuum pump
Sealing Die
Max battery size:
Length ≤ 160 mm
Width ≤ 180 mm
Thickness ≤ 12 mm
Sealing width: 4 mm (The sealing width could be customizable)
Sealing length: ≤ 190 mm
Sealing evenness: ≤ 0.03 mm overlapping precision of top and bottom sealing dies
Sealing die type: Sealing blade with rubber buffer (soft-sealing)
Sealing Pressure
Pressure range: 0 ~ 7 kg/cm² adjustable. The vacuum chamber lid and sealing die need to be driven by compressed high-purity inert gasses with a recommended 60 psi pressure.
Consumption: ~ 0.1 L compressed air per sealing
Please use high purity inert gasses (Ar or N2), when operating in the glove box. Using Air Compressor driven when operating outside the glove box.
Please note that the air compressor is not included and is not recommended for use in the glove box.
Attention: If a gas cylinder is used instead of an air compressor(pic2), a two-stage pressure regulator(pic1) must be installed on the gas cylinder to limit the pressure within the required working range for safe operation.
Dimension
Dimension: 455 mm L x 390 mm W x 600 mm H
Net Weight
~ 55 kg
~ 120 lb
Shipping Weight & Dimensions
180 lbs
40"x26"x34"
Glove Box Compatibility
A KF40 Feedthrough for Glovebox is included in the package.
Please use high purity inert gasses (Ar or N2), when operating in the glove box. Using Air Compressor driven when operating outside the glove box.
DO NOT set the pressure gauge above 90 psi (0.6 Mpa)!
Compliance
CE Certified
NRTL Certification is available upon request at an extra cost
Operation Video
Application Notes
Please wear gloves to operate the machine.
Beware of the automatic vacuum chamber lid. Only one operator is allowed for this equipment.
Please clean the sealing dies after each use. Clean the sealing die after it has cooled down to avoid corrosion by the electrolyte.
Check the level and smoothness of the sealing die surface every week. If there is serious damage to the sealing die, please contact MTI to order a replacement.
Lubricate the cylinder every week
Check the screws in sealing dies and stage every month. Make sure they are tightened.
×
MTI offers a One-Year limited warranty with lifetime support(may cause a fee) for this product.
The MTI One Year Limited Warranty does NOT cover
Consumable parts such as Graphite dies, O-rings, crucibles, screws, washers, etc.
Any damage and rust resulting from improper storage or maintenance.
Any damages caused by the use of corrosive and acidic gases.
Any damage resulting from failing to adhere to the individual product's specific operation requirements, such as water cooling, venting, etc.
Manufacturer Part Number:
.
Choosing a selection results in a full page refresh.