MSK-800-TE9002 is an economic nail penetration tester for all types of rechargeable batteries, which meets the CE standards. The nail penetration is performed inside a safe and vented stainless-steel test chamber using a 2~8 mm diameter steel nail at variable speed from 10~100mm/s. A dedicated fixture for tightening various types of cells, such as pouches or cylinders is installed in the test chamber. This is an essential tool for advanced research on rechargeable batteries.
SPECIFICATIONS:
Power |
- 208V- 240VAC, 300W
- To use the equipment at 110 V, please order a 300W transformer
|
Accessories |
|
Penetration Force |
- 0 ~ 300 kg
- Suitable for single-cell and small battery pack
|
Steel Nails
|
- Seven steel nails (2mm, 3mm, 4mm, 5mm, 6mm, 7mm & 8mm diameter, one each) are included in the standard package, please click the picture on the left to view details
- Length: 100 mm
- Other diameter nails can be ordered upon request
|
Penetration Speed |
|
Dwell Time |
|
Working temperature |
|
Operation Chamber
 Pouch Cell Cylindrical Cell |
- The chamber inside is made of stainless steel to resist fire and is easy to clean
- There is a front observation window which is made of double layers of high-strength glass
- Chamber size: 16" x16 "x 16", (400 x 400 x 400mm)
- Max. sample size can be accommodated: 8" x 8" x 8" (200 x 200x 200 mm)
- Feedthrough ports: One (1) port (50 mm Dia.) with a cap on the left for cords
- Please click the picture to the left to view the details
|
Features on the Back
|
- Pressure Release Door: 200mm (L) x 200mm (H) in the back, which will open for pressure release during an explosion.
- Air Circulation: 100 mm Dia. pipe with an exhaust fan on the back, which may be connected to the vent port in the facility via a tube (not included, please order at a local hardware store)
|
Compliance |
|
Application & Safety Note |
- The max capacity of Li-Ion batteries to be tested in the chamber should be limited to 4.2V@ 40Ah for a single-cell or 160Wh for a battery pack without protection circus
- The equipment must be put in an isolated fire-proof room or fume-hood with a venting & extinguish system
- The operation unit shall be located in the outdoors or fume-hood
|