Double layer stainless steel structure for maximum vacuum and safety, which can endure a positive pressure up to 1MP and vacuum up to 10E-2 Torr
-
Water cooling front door and air cooling shell
-
Built in pressure gauge, vacuum valves and two gas float meters
-
Built in H2 burning control system --- if the controller detects no flame in burner, gas delivery valve will be shut down automatically
|
Inside Chamber Size
|
- Heated chamber: 800x 800x 900 mm (30x30x35 inch), 576 Liter
- Energy saving 1800 grade fibrous alumina insulation
- High purity Al2O3 coating
- The chamber is water cooling from ourside by 1/4" stainless stell pipe weld on
- Warning: One Al2O3 fibrous door block is included. You must place the door block in the front the chamber to block heat radiation, otherwise may damage seal ring at high temperature and cause hydrogem gas leaking
|
Safety Vlaves
|
Two safety valves are installed on the chamber
- One is disc check valve: once pressure > 5 PSI , the disc will crack and release chamber pressure
- Anoter is sspring poston check valve, once pressure > 15PSI, the valve will open to releae pressure and close when pressure reduced
|
Power
|
125KW
|
Voltage
|
AC 460V Three Phase (50/ 60 Hz)
|
Current
|
50 Amp (> 75 Amp air breaker is required)
|
Continuous Working Temperature
|
1600° C
|
Maximum Working Temperature
|
1700°C (< 1 hr)
|
Heating Rate
|
5°C / min
|
Temperature Accuracy
|
+/- 1°C
|
Heating Elements
|
-
9 sets of Mo coils heating elements are built in , and replaceable
- The heating element of Mo coil is consumable parts which should be ordered seperately if extra sets are required. ( order picture below left to order spare )
- Warning: Mo heating element can not be used under air or oxygen at the temperature > 300°C
|
Temperature Control
|
- PID automatic control via SCR (Silicon Controlled Rectifier) power control with phase angle fired, current limiting resistor.
- 30 programmable segments for precise control of heating rate, cooling rate and dwell time.
- Please click here to learn why SCR is more accurate than SSC (Solid state relay).
- Built in PID Auto-Tune function with overheating & broken thermocouple broken protection.
- Over temperature protection and alarm allows for operation without attendant(s).
- +/- 1 ºC temperature accuracy.
- RS485 Communications Port.
- Optional:
- The furnace may be operated by PC by installing a control module. Please order a MTS-02 control module at extra cost.
- If you order the PC control module together with the furnace, we will install and test it before shipping. We recommend you to order a computer laptop from us to avoid software installation problems. For more information please click here
|
Gas Flow Control & Vacuum Valve
|
- Two large flow meters (N2: 0~3.5L/min, H2: 0~3.5L/min) are installed in the front panel of furnace.
- One for purging Inert gas prior to introducing H2 gas
- One for controlling H2 gas flow
- KF40 vacuum pump build in to connect a vacuum p
- Vacuum pump may need , but not included
|
H2 Gas Burning Control System |
- An ignition device already installed to incinerate flowing gas and detect burner temperature to ensure H2 burner is in working condition. If H2 does not burn properly, the controller will shut down the H2 gas delivery valve immediately.
- Warning: You must install a certified Hydrogen detector in operation facility to alarm hydrogen leaking b accident. If you can not find in local store, please click link below to order 3M hydrogen detector from us at extra cost.
|
Water Cooling (optional )
|
A 16L/min recirculating water chiller is installed bottom furnace for cooling furnace sealing flange. ( CE certified only )
|
Net Weight
|
1000Kg
|
Overall Dimensions
|
TBD
|
Shipping Weight
|
TBD
|
Warranty
|
- One year limited warranty with life time support. (Consumable parts such as sample plates and heating elements are not covered by the warranty, please order the replacement at related products below.)
- ATTENTION: Any damages caused by the use of corrosive and acidic gases are not under the coverage of MTI One Year Limited Warranty.
|
Compliance
|
- CE Certified
- All electric components ( >24V) are UL / MET / CSA certified
- The furnace is ready to pass TUV(UL61010) or CSA certification at extra cost. please click mark below to learn details )
-
|
Application Notes
|
- Please EXERCISE EXTREME CAUTION. H2 gas is highly flammable and explosive. H2 ignites at a temperature of 400°C, an explosion could occur when the hydrogen content reaches 4.0%-74. 2% in the air, please strictly follow the rules below to for safety operation.
|