MSK-PCV-30 is a high-energy planetary-centrifugal mixer with six 30 ml containers, which can mix six kinds of samples such as dry powders, pastes and slurries at the same time. This device is Ar gas compatible.
SPECIFICATIONS
Voltage Input |
- Single Phase AC 208 - 240V, 50/60 Hz, 350W
- 110V version is available via a transformer ( 110AC- 220CAC)
|
Power |
- Maximum: 450W
- Motor Power: 400 W
|
Mixing
|
- Planetary Centrifugal Vacuum Mixing
- The centrifugal force of rotation and revolution induces convection, homogenizing the materials
- With the vacuum pressure, submicron air bubbles can be efficiently eliminated from the materials
- Max, Gravity acceleration: 438 G
- Max viscosity: 30,000 Pa S
-
Speeds: Fixed speed ratio (0.6X between main plate revolution and container rotating)
- Sample Platen Rotation (revolution motion): 300 rpm - 2,000 rpm (adjustable)
- Container Spin (rotation motion): 180 rpm - 1,200 rpm (fixed at 0.6X of the revolution speed)
|
Containers
|
- Six 30 ml containers made of high-density Polyethylene, are included
- Max. weight for each container+ sample is 100 g ( wet mixing ) , and 50g ( dry mixing)
- Six containers' weight must be the same.
- Customized container sizes may available upon request at an extra cost
|
Vacuum |
- One 1/4 " vacuum port is located on the outside case to connect to a vacuum pump
- One156L/minute rotary vacuum pump with pipe is included
- Max. vacuum: -0.1 Mpa
|
Control Panel
|
- Touch screen control panel to program speed and time
- Store up to 8 programs in memory, as shown in Fig.1
- 3 segments, as shown in Fig.2. For example:
- 800 rpm revolution speed (480 rpm rotation speed) for 60 sec;
- 1500 rpm revolution speed (900 rpm rotation speed) for 180 sec;
- 1000 rpm revolution speed (600 rpm rotation speed) for 60 sec.
- The maximum running time for each segment is 200 sec. The maximum total running time is 600 sec
|
Safety and Protection |
- Safety warnings and interlocks are integrated. The unit automatically stops when
- The unit is overloaded with the sample
- The sample is loaded in an unbalanced way
- The top cover is opened
|
Compliance |
- CE certified
- NRTL or CSA certification is available upon request at the extra cost
|
Application Notes |
- Always use the mixer on a level & stable surface for best performance and maximum safety
- Do not use the mixer in a hazardous atmosphere, or with flammable, explosive, corrosive, poisonous material! Check the chemical resistance of the container with different materials before loading the sample!!!
- Do not overload the mixer! Stop the mixing operation immediately if abnormal sound/vibration is observed
- Use a digital balance to make sure the sample loading is balanced before mixing
- Double-check if the containers are mounted correctly and securely before mixing
- Do not open the cover lid until the rotation has completely stopped! Do not retrieve the containers and/or put a hand close to the mixing fixture while the rotation has not completely stopped!
- Only use the included containers for the mixing operation! Double-check to make sure there is no foreign object in the mixer before mixing
- Please click underline to learn Centrifugal Force calculation
-
Please do not use it under Ar gas. Please consider our MSK-PCV-310AR if Ar gas is required
|