OTF-1500X-III- is a split three-zone tube furnace with mullite tube and conventional flange working up to 1500°C. Three 30 segments temperature controllers are installed with S type thermal couples and  +/ - 1°C accuracy. It is an excellent furnace for exchanging processing tube for multi-purpose.  

Note: New safety feature: An interlock system has been integrated into the furnace structure since June.2015

SPECIFICATIONS:

Power Input 9KW
Working Voltage  AC220V Single-phase 50/60Hz ( 50 A breaker required)
Max. Working Temperature 1500°C < 1 hours
Continuously Working Temperature 1400°C
Recommend Heating rate 5°C/min
Processing Tube

Tube material: Alumina Tube
Size: 80 OD × 74 ID × 1200 L  mm
Optional tube material: Mullite tube
Size:   82 O.D x 73 I.D x 1200mm L 

Heat Zone Length
  • Three heating zones:  200 mm / each  (Included 20 mm spacing)
  • Total heating zone length:  600 mm  
  • Constant Temperature Zone length:   350mm  (If set 3 zone at same temperature) +/- 2ºC.
  • Accept processing tube up to 100 mm diameter

Temp. Profile at 1450ºC

84mm O.D Tube
(click to enlarge)
Overall Dimensions 915 mm × 660 mmW × 762 mmH
Temperature Controllers

  • PID automatic control with 30 programmable segments for precise control of heating rate, cooling rate and dwell time.
  • Built-in overheating & broken thermocouple protection.
  • Over-temperature protection and alarm allow for operation without attendant(s).
  • +/- 1 ºC temperature accuracy.
  • Three S-type thermocouples (one for each zone).
  • RS485 Communications Port.
  • Optional:  
    • The furnace may be operated by PC by installing a control module. Please order an MTS-02 control module at extra cost. 
    • If you order the PC control module together with the furnace, we will install and test it before shipping. We recommend you to order a computer laptop from us to avoid software installation problems. For more information please click here.
                   
European Temperature Controllers (optional upgrade)
  • 1 heating channel
  • 1 program of 8 or 24 segment
  • Alarm Relay: Form 'A' and Form ‘C’ built-in 
  • Digital Communications: RS485
  • Temperature Accuracy:  ±  0.1ºC
  • Recipes: Using a PC tool recipes can be created that can be used to change the operating parameters of the 3000 simply by selecting a new recipe via the HMI. This is very useful where multiple products are processed using the same controller but require different parameters to be set.
Laptop, software & WiFi Control(Optional)
    
  • Brand new laptop with Microsoft Windows 10 and Microsoft Office 2013 (30 days free trial) 
  • Labview Based Temperature Control System (EQ-MTS01) enables the user to edit temperature profiles, manage heat-treatment recipes, record and plot data for MTI furnaces.
  • A wireless remote control provides up to 300 meters of operating range.
  • The above features are available upon request at an extra cost (up to $1,000).
Vacuum Level
  • 10E-2 torr by quality mechanical vacuum pump
  • 10-5 torr by molecular pump

Thermal Block Placement
  • Two thermal blacks are included. Please click the picture below to learn how to place them inside tube
  • You may order flange support to avoid tube rotating ( click Pic below right )
  
Heating Elements & Thermal couples
   
          
Dimension & Net Weight  860 L x 540 W x 750 H (mm)  Weight: 160 Kg
Shipping Weight & Dimensions 465 lbs; 52" x 40" x 46"

Application Notes
  • The tube furnaces with mullite tubes are designed for use under vacuum and low pressure < 0.02 Mpa
  • Never use the graphite crucible and the alumina tube.
  • Attention: A two-stage pressure regulator must be installed on the gas cylinder to limit the pressure to below 3 PSI for safe operation. 
  • The flow rate for gases should be limited to < 200 SCCM ( or 200ml/min )
  • Vacuum pressures may only be safely used up to 1300°for all mullite tube furnaces:
  • Customized long heating zone up to 1200 mm L  with 700 mm uniform temperature zone ( +/- 5°C) , and 1800mm mullite tube is available upon request; ( click the picture below to see sketch)
  • 5 zones     6 zones
Operation Instructions


Warranty
  • One-year limited warranty with lifetime support (consumable parts such as processing tubes, and O-rings are not covered by the warranty, please order replacements at related products below.).  
  • ATTENTION: Any damages caused by the use of corrosive and acidic gases are not under the coverage of MTI One Year Limited Warranty.


Compliance
  • CE Certified
  • NRTL (UL61010) or CSA certification is available upon request at extra cost.

MTI offers a One-Year limited warranty with lifetime support(may cause a fee) for this product.

The MTI One Year Limited Warranty does NOT cover

  • Consumable parts such as O-rings, crucibles, screws, washers, etc.
  • Any damage and rust resulting from improper storage or maintenance.
  • Any damages caused by the use of corrosive and acidic gases.
  • Any damage resulting from failing to adhere to the individual product's specific operation requirements, such as water cooling, venting, etc.