Skip to product information
1 of 1

Split-able Pouch Cell for Battery R&D (65Lx45Wx19Tmm) - EQ-SPC-654519

Split-able Pouch Cell for Battery R&D (65Lx45Wx19Tmm) - EQ-SPC-654519

Out of stock

Regular price $800.00 USD
Regular price Sale price $800.00 USD
Sale Email for Lead Time

SKU: : \SPC654519N

Material
View full details

EQ-SPC-654519 is splitable pouch cell made of Nylon or Peek which is designed for testing pouch cell with max electrode dimension of  60mm H x 45mm L x 19 mm wide  Its detachable design allows you to test the pouch cell behavior as well as structural changes of electrode easily, quickly and cost effectively.

Specifications
Design
  • Easy assembling by only four cap mounting screws
  • Easy to separate after test for microstructure analysis
  • Space saving, compact design allows you put it into the glove box
Material
  • Nylon or PEEK (Poly Ether Ether Ketone) selectable from product options bar
  • Body: Electrolyte corrosive-proof Nylon which can sustain with temperature up to 80ºC  and O-ring: Sealed by electrolyte corrosive-proof PTFE O-rings
  • Body: PEEK (Poly Ether Ether Ketone), which is a semicrystalline thermoplastic with excellent mechanical and chemical resistance properties that are retained to high temperatures and O-ring: Sealed by electrolyte corrosive-proof FKM O-rings

Dimensions & Structure
  • Inside chamber:      65 mm H  x  45mm W x19 mm Thick
  • Suggested Max. electrode area:    60mm H x 40 mm 
  • Outside Case    89 mm H x 75 mm W x  53 mm Thick
  •        
  • One digital pressure gauge installed on top to monitor pressure.  You may remove the gauge and use 1/4 female port to inject electrolyte into the pouch cell
  • Two stainless steel contacts to connect anode and cathode by the screw.
  • Max. working temperature:  80°C.for Nylon, and 120oC for PEEK
  • Max. working pressure: 36psi (0.25MPa) for Nylon and 60psi (0.4Mpa) for PEEK
  • Customized size split pouch cell are available upon request
Application Note
  • In order to make metal air pouch cell, you can drill holes on the case. We can help you do that at extra cost
  • You may use MTI die cutter to prepare electrode via layer by layer or make winding type pouch cell electrode ( click picture below to see the machine
  • You may need a ultrasonic welder to welding electrode tape  to connect to the split cell
                         
 
     Die cutter         Ultrasonic Welder       Winding Machine    Pre-coated Electrodes     Other split cells

Manufacturer Part Number: