OTF-1200X-III-80-F3LV  is a splittable three zones Tube furnace with a mechanical vacuum pump & digital vacuum gauge and three channels gas flowing system, which can achieve vacuum up to 10-2 torr and mix 1-3 types of gases for CVD or diffusion. This furnace system also includes an anti-corrosive Pirani Capacitance Diaphragm Gauge to enable vacuum measurements with aggressive gases.

SPECIFICATIONS

Furnace Construction
  • Double-layer steel casing with air cooling
  • High-purity alumina fiber insulation for max. energy saving
  • Splittable cover for easy tube replacement

Power Consumption

5 KW

Input Voltage

AC 208-240V Single Phase, 50 or 60 Hz 

Maximum Temperature

1200 oC

ContinuousTemperature

1100 oC

Maximum Heating Rate

<= 20 oC /min

Heating Zone Length

  • Three zones: (880mm, 35" in total)
    • Zone 1: 220mm  (8.6" )
    • Zone 2: 440mm  (17.3")
    • Zone 3: 220 mm (8.6")

Constant Temperature Zone

  • If three zones are set at the same temperature, the constant temperature zone is 25" (625 mm) long with a temperature discrepancy of +/- 1oC.
  • If using only one zone (center zone), the constant temperature zone is 4.3" (110 mm) long with a temperature discrepancy of +/- 1oC.

Temperature Accuracy

+/- 1oC

Heating Elements

Fe-Cr-Al Alloy doped by Mo

Temperature Controller

  • Three precision temperature controllers to control three zones separately.
  • PID automatic control with 30 programmable segments for precise control of heating rate, cooling rate, and dwell time.
  • Built-in overheating & broken thermocouple protection.
  • Over temperature protection and alarm allows for operation without attendant(s).
  • +/- 1 ºC temperature accuracy.
  • RS485 Communications Port.
  • Optional:  
    • The furnace may be operated by PC by installing three control modules. Please order the MTS-02 control modules at an extra cost. 
    • The new version of PC module is now compatible with Lab View 05/08/2014
    • If you order the PC control module together with the furnace, we will install and test it before shipping. We recommend you to order a computer laptop from us to avoid software installation problems. For more information please click here.

                   
         

Quartz Tube& Sealing Flanges
Vacuum Sensor & Display

Sliding Flange with Sample Holder
Vacuum Sealing Flanges

  • Two stainless steel flanges with both vacuum gauge and valves included.
  • Min. vacuum pressure achieved by the mechanical pump is 5.5 m-torr. ( 5.5x10^-3 torr). The pressure can reach 10^-5 torr by using a mechanical + molecular pump.
  • The leaking rate is < 5 m-torr / min. and stable vacuum pressure after 24 hours is < 2 torr.
  • Click the picture below to get a details chart and data measured by CE certified vacuum meter:        

(For a whole 24 hours curve display, the time segment through 08:00:00~21:10:00 in X axis is passed over in the chart, therefore, steep variety in there)

Oxygen Monitoring

An Oxygen Sensor can be used to monitor the oxygen level of gas(es) used in CVD systems for preventing or reducing oxidation. Please click the picture below to learn more:
         

Vacuum Pump

  • 120 L/m Rotary Vane Vacuum Pump is included with max. vacuum pressure of 10^-2torr. Stainless steel hose tube is included for connecting to the tube furnace.
  • Option: For precise control of the vacuum pressure, we recommend you choose our turn-key solution EQ-VPC-MV. This is a vacuum pressure regulating system with a motorized valve and gauge. It controls pressure range from 10^-6 torr ~ 760 torr.


Gas Flow Meter and Pressure MeterNew Version front panel
  • Three gas flow meters (4% accuracy FS) are installed inside the mobile case to enable monitoring of gas flowing rates (three different kinds of gases in total).
    •  Compact direct read flow meter, 10-100 cc/min.
    •  Compact direct read flow meter, 16-160 cc/min.
    •  Compact direct read flow meter, 25-250 cc/min.
  • Four pressure meters are installed inside the mobile cart which is able to monitor three types of flowing gas pressure as well as the pressure of the mixing tank.
Valves Four stainless steel valves are installed in the side panel of the mobile cart to control the mixing of three inlet gases separately

Dimensions

  • Furnace: 1100 X 450 x 670 mm
  • Bottom Mobile case: 600x600x597 mm

Shipping Weight

 850 Lbs

Shipping Dimensions

Total Three Pallets
#1: 60" x 45" x 40"
#2: 48" x 40" x 42"
#3: 48" x 40" x 42"

Warranty

One-year limited manufacturer's warranty (Consumable parts such as processing tubes, O-rings, and heating elements are not covered by the warranty, please order replacements at related products below).

Manufacturer Part Number: